System requirements for FactoryTalk ViewPoint 16.00.00
Hardware Requirements
For the optimal performance of publishing applications, the personal computer is recommended to meet or
exceed the following hardware requirements:
- Intel® Core™ i5 Standard Power processor
- 4 GB of memory (RAM)
FactoryTalk ViewPoint for Machine Edition requires the following PanelView™ Plus graphic terminal
hardware:
The following mobile devices are supported and recommended:
- iPad® Pro with IOS 18.5
- Samsung Galaxy Tab® S9 with Android 15.0
- Samsung Galaxy® S24 with Android 15.0
- Surface® Pro10 with Windows 11 Pro
- iPhone 15 Pro with IOS 18.5
- iPhone 16 Pro with IOS 18.2
Operating systems
The following operating systems are supported and recommended* for the FactoryTalk ViewPoint server:
- Windows Server® 2025 Standard (Recommended OS)**
- Windows Server 2022 Standard (Recommended OS)**
- Windows Server 2019 Standard**
- Windows® 11 Enterprise (Recommended OS)
- Windows 11 Professional (Recommended OS)
- Windows 11 Enterprise 2024 LTSC 64-bit (v24H2)
- Windows 11 IoT Enterprise 2024 LTSC 64-bit (v24H2)***
- Windows 10 Enterprise 64-bit
- Windows 10 Professional 64-bit
- Windows 10 Enterprise 2021 LTSC 64-bit (v21H2) (Recommended OS)
- Windows 10 IoT Enterprise 2021 LTSC 64-bit (v21H2)***
- Windows 10 Enterprise 2019 LTSC 64-bit (v1809)
**Windows Server Datacenter editions are supported. The key difference between Windows Server
Standard and Datacenter edition is how Microsoft licenses the operating system. Windows Server
Standard includes licensing for up to two virtual machines per core license,
making it suitable for lightly virtualized environments. Datacenter edition allows unlimited virtual machines per
core license, offering better value for highly virtualized or cloud-scale deployments.
***Windows 11 IoT Enterprise LTSC and Windows 11 Enterprise LTSC are binary equivalents but are
licensed differently. Windows 10 IoT Enterprise LTSC and Windows 10 Enterprise LTSC are binary
equivalents but are licensed differently.
Rockwell Automation's software installation policy is based on the lifecycle information of Microsoft
operating systems. If an operating system's lifecycle state is approaching its end, you may encounter a
warning message when trying to install Rockwell Automation software on it.
|
Microsoft lifecycle policy
|
Rockwell Automation installation warning policy
|
Rockwell Automation installation prevention
policy
|
|
Fixed
|
Present a warning message during installation on
Microsoft operating systems that are 18 months
before Microsoft's extended end date.
|
Prevent installation on Microsoft operating systems
that are six months past Microsoft's extended end
date.
|
|
Modern
|
Present a warning message during installation on
Microsoft operating systems that are 18 months
before Microsoft's retirement date.
|
Prevent installation on Microsoft operating systems
that are six months past Microsoft's retirement date.
|
|
Operating system
|
Microsoft lifecycle
policy
|
Extended end date
|
Retirement date
|
Installation warning
|
Installation prevented
|
|
Windows 11 Enterprise
and Professional
editions
|
Modern
|
None
|
None
|
None
|
None
|
|
Windows 10 Enterprise
and Professional
editions
|
Modern
|
None
|
October 14, 2025
|
April 14, 2024
|
April 14, 2026
|
|
Windows Server
2025 Standard
and Datacenter
editions
|
Fixed
|
October 10, 2034
|
None
|
April 10, 2033
|
April 10, 2035
|
|
Windows Server
2022 Standard
and Datacenter
editions
|
Fixed
|
October 14, 2031
|
None
|
April 14, 2030
|
April 14, 2032
|
|
Windows Server
2019 Standard
and Datacenter
editions
|
Fixed
|
January 9, 2029
|
None
|
July 9, 2027
|
July 9, 2029
|
Required software
FactoryTalk ViewPoint for Site Edition is an add-on to an existing FactoryTalk View system and requires
FactoryTalk View version 16.00.00. FactoryTalk ViewPoint for Site Edition automatically installs the following
required software on the host computer, if necessary:
- FactoryTalk Services Platform version 6.60.00
- FactoryTalk Alarms and Events version 6.60.00
- FactoryTalk View Site Edition Client version 16.00.00
- Internet Information Services
- Microsoft® .NET Framework 4.8
FactoryTalk ViewPoint for Machine Edition is an add-on to an existing FactoryTalk View system and
requires FactoryTalk View version 16.00.00.
FactoryTalk ViewPoint for Machine Edition automatically installs the following required software on the host
computer, if necessary:
- FactoryTalk Services Platform version 6.60.00
- Microsoft® .NET Framework 4.8
Supported Browsers
The following web browsers are supported for use with this release:
- Chromium-based Microsoft Edge™
- Google® Chrome™ browser
- Mozilla® Firefox®
The following mobile web browsers are supported for use with this release:
- Apple® Safari®
- Google Chrome browser
Windows Firewall Program and Services exception list
Firmware requirements
FactoryTalk View ME can create Machine Edition Runtime applications (.mer) that run on PanelView Plus
graphic terminals. The PanelView Plus firmware must support the .mer file to host FactoryTalk ViewPoint
content.
|
PanelView Plus Terminal Firmware Revision
|
Machine Edition Runtime Version
|
FactoryTalk ViewPoint Content (contained in
.mer)
|
|
16.00-2025mmdd or later
|
16.00
|
16.00
|
|
15.00-2024mmdd or later
|
15.00
|
15.00
|
|
14.00-2023mmdd or later
|
14.00
|
14.00
|
|
13.00-2022mmdd or later
|
13.00
|
13.00
|
|
12.00-2020mmdd or later
|
12.00
|
12.00
|
|
11.00-2019mmdd or later
|
11.00
|
11.00
|
|
10.00-2018mmdd or later
|
10.00
|
10.00
|
|
9.00-2016mmdd or later
|
9.00
|
9.00
|
|
8.20-2016mmdd or later
|
8.20
|
8.20
|
|
8.10-2015mmdd or later
|
8.10
|
8.10
|
|
8.00-2014mmdd or later
|
8.00
|
8.00
|
|
7.00-2012mmdd or later
|
7.00
|
2.60
|
|
6.1-2011mmdd or later
|
6.10
|
2.10
|
|
6.0-20110425 or later
|
6.00
|
1.20 or 2.00
|
|
5.10.01 or later
|
5.10
|
1.10
|
Security requirements
To learn about designing a secure networking environment, review this publication:
To learn about implementing application-level security using FactoryTalk Security, review this publication:
- FactoryTalk Security Application Technique (publication SECURE-AT002) explains how to use
FactoryTalk Security to implement authentication and authorization in your industrial automation
system and how to enforce product-specific security for applications like Studio 5000 Logix Designer,
FactoryTalk View, and FactoryTalk AssetCentre.
To learn about designing and implementing an architecture with device-level security using CIP Security,
review these publications:
Application notes for FactoryTalk ViewPoint for Site Edition.
Unsupported FactoryTalk View features
Graphic displays that contain unsupported objects or features can still be published to a FactoryTalk
ViewPoint server and viewed in a web browser. During the publishing process, unsupported objects are
removed from displays, so that they do not interfere with the web application.
Each unsupported object or feature generates a warning during publishing, which is recorded in the
publishing report. To check the report, after publishing is finished, click the link View publishing report.
FactoryTalk ViewPoint does not support the following FactoryTalk View objects or features:
Impact of Microsoft deprecating VBScript
Microsoft announced the phased deprecation of VBScript in 2024. VBScript is now an optional feature beginning in Windows 11 24H2 and Windows Server 2025. Many FactoryTalk software products released before September 1, 2026, use VBScript during installation.
FactoryTalk ViewPoint Site Edition versions 16.00.00 and earlier require VBScript for installation. Installation will fail if VBScript is not enabled.
To mitigate the problem, enable VBScript manually. For more information, see the Knowledgebase Document ID: IN41397 - Impact of Microsoft deprecating VBScript. FactoryTalk software products released after September 1, 2026, no longer rely on VBScript.
Graphic display properties
- Resize and position settings are ignored when a display is opened in a web browser. Displays
are scaled to fit the web browser window by default.
- Startup and shutdown commands are not supported.
- A to P codes for securing displays at run time are not supported.
- Macros defined on screens are not supported.
- Display keys are not supported.
- Track Screen for Navigation and Track Name are not supported.
- FactoryTalk ViewPoint does not support docking the navigation menu to the right or left, or docking
submenus.
Graphic objects and object properties
- FactoryTalk ViewPoint does not support the built-in runtime search functionality on the runtime
navigation menu.
- FactoryTalk ViewPoint does not support:
- Gauge
- Key
- OLE
- ActiveX controls
- Electronic signature
- Advanced objects: arrows, piloted control list selectors, and recipe
- .Net controls, excluding EChartsWidget
- Toggle switch
- Linear gauge
- FactoryTalk ViewPoint does not support the Use parameter placeholder for initial URL function of the
Web Browser graphic object.
- FactoryTalk ViewPoint only supports the show exponent format for the following graphic objects:
- Numeric input
- Numeric display
- TrendX
- FactoryTalk ViewPoint only supports dynamic decimal places for digital and analog tags. String tags are
not supported.
- Multistate objects that cannot get tag data will show in outline form, instead of showing an Error state.
- Objects with a gradient back color are shown in FactoryTalk ViewPoint with a solid color using the
start color of the gradient. Trend objects show with a white background.
- Tooltip text is only supported for numeric display, numeric input, string input, string display,
Ramp button, Momentary, button, Multistate button, and Maintained button.
- The FactoryTalk View SE Button object only supports Set, Ramp, = (Equal), Toggle, Display, and
Abort commands. These commands can be executed individually, serially, or from a macro.
-
Alarm and Event log viewers and status explorers are not supported. When detected in a display,
a FactoryTalk alarm and event summary is replaced with a FactoryTalk ViewPoint alarm
summary.
Alarm and event commands for selected alarms on the alarm summary are not supported.
-
Navigation commands (such as DisplayPreviousScreen) are not supported. The web application can
be published, but the navigation command will not be executed in FactoryTalk ViewPoint. Likewise, a
FactoryTalk View SE application containing a NavigationButton object can be published, but the
object is omitted from the web application.
-
Objects with a Pattern Style property in FactoryTalk View are shown without the pattern in the
published FactoryTalk ViewPoint application.
To avoid this problem, do not use Pattern Style properties to communicate any critical state or
message in a FactoryTalk ViewPoint application.
- Delay could be longer than the momentary push button's Hold Time property. The nature of Internet
traffic does not guarantee that the server receives data packets in the same order that the client sent
them. When an On Press or On Release event occurs for a momentary push button, FactoryTalk
ViewPoint waits for a server response before sending the next value. FactoryTalk ViewPoint uses
the longer of the following two times:
- The specified Hold Time
- The time it takes to receive a response from the server that the On Press or On Release event was
received
- When a display contains both control objects with tags and control objects without tags, control
objects without tags are shown differently in the browser window than they are on the graphic
terminal.
- When detected in a display, a FactoryTalk View trend object is replaced with a FactoryTalk ViewPoint
trend.
- FactoryTalk ViewPoint trends do not support displaying FactoryTalk® Historian Site Edition Asset
Framework data.
- FactoryTalk ViewPoint trends do not support FactoryTalk Historian SE annotations.
- FactoryTalk ViewPoint does not support displaying historical data on an XY Plot.
- FactoryTalk ViewPoint trend does not support the following properties specified in the Trend Properties
dialog box:
|
Tabs
|
Properties
|
|
General
|
- Unsupported: None
- Display progress bar while loading historical data
- Chart style: XY Plot
- Chart update mode, except for Automatic
Refresh Rate, which is supported
|
|
Display
|
- Chart display options, except for Chart radix and
Background color, which are supported
- Current value legend
- Line legend, except for Pen caption, which is supported
- Scrolling
|
|
Pens
|
- Pen Attributes, except for Tag\Expr., Model, Color,
Visible, Width, Min, Max, and Description, which are
supported
|
|
X-Axis
|
- Chart time range, except for Time span, which is
supported
- Display options, except for Display Scale, which is
supported
|
|
Y-Axis
|
- Display options, except for Display Scale, which is
supported
- Scale options
- Minimum / maximum value options: Custom -
Controlled by tag
|
|
Overlays
|
All
|
|
Templates
|
All
|
|
Common
|
Other
|
- FactoryTalk ViewPoint trends do not support the following TrendPro object properties:
|
Tabs
|
Properties
|
|
Common
|
- Name
- Focus highlight
- Pointer Highlight
- Key navigation
|
|
Tabs
|
Properties
|
|
|
|
|
Time Period
|
- Manual update mode
- Time zone
|
|
Chart
|
- Margins
- Tooltips
- Zoom and Pan
- Automatic scaling
- Background, except for Canvas color, which is
supported
- Cursors
- Trace layout
- Use current trace label
|
|
X-Axis
|
All
|
|
Application
|
All
|
|
Live Data
|
All
|
|
Retrieval
|
All
|
|
Y-Axis
|
- Label
- Axis
- Minimum / maximum value options: Custom -
Controlled by tag
- Mode
- Tick marks
|
|
Trace
|
- Display statistics
- Display trace line
- Display direction arrows
- Point markers color
- Point markers size
- Plotting algorithm
- Discrete and time tags
- Engineering units
|
- The Enter and Enter Handshake connections are not supported.
Object animation
- Horizontal and vertical sliders show current positions only. The sliders do not respond when dragged.
- Object keys are not supported.
- Supports dynamic decimal places for the following graphic objects:
- Numeric input object in the Floating point or Show exponent format
- Numeric display object in the Floating point or Show exponent format
- The number of places after the decimal point changes dynamically based on the linked tag value.
- Supports hyperlink animation only when the hyperlink includes http:// or https://.
- If the hyperlink is an absolute path to a public web resource, for example,
http://literature.rockwellautomation.com/idc/
groups/literature/documents/qs/ftvp-qs002_-en-e.pdf, clicking the graphic object will open the
hyperlink destination on a new tab page.
- If the hyperlink is a local web resource, for example, http://ComputerName/ftvp-qs002_-en-e.pdf,
where ComputerName is the name or IP address of the intranet web server computer hosting the resource, to open the hyperlink destination, you need add a virtual directory in the IIS Manager. For more information about how to configure IIS, see "Configure IIS for hyperlink animation" in FactoryTalk View SE Help.
Logic and control functions
- Client keys are not supported.
- FactoryTalk ViewPoint only supports the following commands:
- Abort
- Display
- Equal
- Ramp
- RecipeProDownload
- ScriptExecute
- Set
- Toggle
- AE_Acknowledge
- AE_ClearCount
- AE_Disable
- AE_Enable
- AE_Remark
- AE_Reset
- AE_Shelve
- AE_Suppress
- AE_Unshelve
- AE_Unsuppress
- FactoryTalk ViewPoint cannot show the following commands’ execution results in the status bar:
- Set
- AE_Acknowledge
- AE_ClearCount
- AE_Disable
- AE_Enable
- AE_Remark
- AE_Reset
- AE_Shelve
- AE_Suppress
- AE_Unshelve
- AE_Unsuppress
View the execution results in FactoryTalk Diagnostics Viewer.
- Visual Basic for Applications (VBA) is not supported.
- FactoryTalk ViewPoint does not support functions.
- PrimaryServerStatus and SecondaryServerStatus return "-2147483647" or "0x80000001" only,
which means unknown.
- The CurrentUserHasgroup(UserGroupName) security function in FactoryTalk ViewPoint does
not support Windows-linked user groups. CurrentUserHasGroup("Windows-Linked UserGroup")
always returns a period (.).
Local message files
Unattended or silent install
Use command-line parameters to perform an unattended or silent installation of the software.
Command-line parameters
The following table identifies the installation command-line parameters. Command-line parameters are
case-insensitive. However, if a specified value includes a space, be sure to enclose the value in quotation
marks (for example, "value with spaces").
|
Parameter
|
Description
|
|
/?
|
Shows the usage options for installation parameters.
|
|
/Q
|
Silent Install, install runs in a quiet mode without any user interface. This parameter is recommended when deploying the software installation using an IT tool or script, and don’t expect any error or restart messages. When using this parameter, check the error codes, and respond as needed. For example, if the installation returns error code 1641, then the IT tool or script should restart the computer and relaunch the installation after restart. This parameter is required if /QS is not specified.
|
|
/QS
|
Unattended Install, install runs in a quiet simple mode and shows progress through the UI, it does not accept
any input but still shows error or restart messages.
When using this parameter, the installation will stop and display a prompt if there are error or restart
messages. For example, if an immediate restart is required to complete the install, a restart message will be
displayed to confirm the restart. Installation resumes automatically from the point of interruption after restart.
This parameter is required if /Q is not specified.
|
|
/IAcceptAllLicenseTerms
|
Acknowledges acceptance of the license terms.
This parameter is required for /Q or /QS parameters.
|
|
/AutoRestart
|
Automatically restarts the computer after the installation is complete. Used when a restart is required to
complete the installation.
This parameter is optional. If this parameter is not used silent install (/Q) will return either error code 1641 or
3010 if a restart is required, and unattended install (/QS) will result in a confirmation prompt that must be
agreed to before the installation is completed.
|
|
/Record
|
Records the installation options chosen to a recording file. When applied, the installation process automatically
creates a recording file
<Product>.REC that is stored in this path:
%USERPROFILE%\Desktop. This parameter is
optional.
|
|
/Playback="value"
|
Plays back a recording file to specify the installation options. The value is the full path of
the REC file to be used. For example,
/Playback="C:\Users\<Username>\Documents\<Product>.REC". This parameter is optional.
|
|
/Repair
|
Runs a repair operation on the installed
products. This parameter is optional.
|
|
/Uninstall
|
Uninstalls the product.
|
|
/SetupLanguage="value"
|
Specifies which language will be shown during the
install process. The value must be one of the
following:
- ENU
- CHS
- DEU
- ESP
- FRA
- ITA
- JPN
- KOR
- PTB
For example, /SetupLanguage="ENU". This parameter is optional. If this parameter is not used, the default language is the current user or operating system user interface language.
|
|
/InstallDrive="value"
|
Specifies the
installation drive.
For example,
/InstallDrive="D:".
This parameter is optional. If this parameter is not used, the default install drive is C:.
|
|
/IgnoreWarning
|
Specifies that the setup ignores warnings and continues.
This parameter is optional. If it is not specified, the setup exits when a warning occurs.
|
|
/SerialNumber="value"
|
Specifies the serial number of the software being installed. This is used to activate the software during
installation.
This parameter is optional. If it is not specified, the software must be activated manually after installation
if activation is required. Some software does not require activation. If activation is not required, this
parameter is not available.
|
|
/ProductKey="value"
|
Specifies the product key used to get activation keys during installation.
This parameter is optional. If it is not specified, the software must be activated manually after installation
if activation is required. Some software does not require activation. If activation is not required, this
parameter is not available.
|
|
/Version="value"
|
Specifies the version of the software to activate, which corresponds to the product version associated with the
SerialNumber and ProductKey. This parameter is optional. If it is not specified, the installer will use the most
recent product version available.
Some software does not require activation. If activation is not required, this parameter is not available.
|
|
/NoHTTPS
|
Specifies that the setup turns off HTTPS.
This parameter is optional. If it is not specified, the setup turns on HTTPS for communication, and a TLS
certificate must be configured after installation.
|
Error codes
The following table identifies the error codes that can be returned by an installation.
|
Error Code
|
Value
|
Description
|
|
ERROR_SUCCESS
|
0
|
The installation completed successfully.
|
|
ERROR_INVALID_PARAMETER
|
87
|
One of the parameters was invalid.
|
|
ERROR_INSTALL_USEREXIT
|
1602
|
The installation was canceled by the user.
|
|
ERROR_INSTALL_FAILURE
|
1603
|
A fatal error occurred during installation.
|
|
ERROR_BAD_CONFIGURATION
|
1610
|
The configuration data for this product is
corrupt. Contact your support personnel.
|
|
ERROR_SUCCESS_REBOOT_INITIATED
|
1641
|
The installer has initiated a restart. After
restart, the installation will continue.
|
|
ERROR_SUCCESS_REBOOT_REQUIRED
|
3010
|
A restart is required to complete the
installation. After restart, the product is
successfully installed.
|
|
ERROR_REBOOT_PENDING
|
3012
|
Restart pending. Restart the computer for the
installation to continue.
|
|
ERROR_SUCCESS_NOT_APPLICABLE
|
3013
|
The installation cannot proceed because the
products are already installed.
|
|
ERROR_SUCCESS_WARNING_REBOOT
|
3014
|
The installation succeeded with warnings.
Check the installation log file for details. To
complete the installation, restart the computer.
|
Installation or upgrading
Installation
- HTTPS enabled by default
If you install FactoryTalk ViewPoint for Site Edition, the installation enables HTTPS by default.
If HTTPS is enabled, you must configure a certificate after installation. If you do not configure the
certificate, there will be unexpected errors when operating FactoryTalk ViewPoint. For details on
configuring a certificate, see FactoryTalk ViewPoint Quick Start Guide.
- FactoryTalk ViewPoint cannot be uninstalled if Internet Information Services
(IIS) is uninstalled first. To avoid this problem, uninstall FactoryTalk
ViewPoint first.
- Installing FactoryTalk ViewPoint Server on a computer with FactoryTalk View Studio for Machine
Edition installed alters Studio behavior. After installing the FactoryTalk ViewPoint Server on an
Engineering workstation that has only FactoryTalk View Studio for Machine Edition installed, Studio
behaves as if a full install of FactoryTalk Supervisory Edition was done.
Upgrading FactoryTalk ViewPoint from version 8.00.00 or earlier
Upgrading to FactoryTalk ViewPoint version 10.00.00 from version 8.00.00 or earlier changes existing
FactoryTalk ViewPoint application and object behavior. Review the following list to determine if design or
configuration changes are required in your application before performing an upgrade.
Republish all displays and download a new .mer file to each terminal after upgrading to FactoryTalk
ViewPoint version 10.00.00.
Trend
-
When the trend object is drawn small or scaled to a small device, the pen legend and X-axis scroll
bar is hidden to help maximize the displayed trend area. Choose trend settings to re-enable. The
smallest size that the alarm object will draw or scale down to is 300x400 pixels. [TFS 62868,
64564, 63838]
- The Y-axis of the trend object is automatically rendered based on the size of the browser window.
Custom Y-axis settings may not be displayed if the size of the browser window is very different from
the original display size. [TFS 69476]
- The trend object will always be drawn completely, even if it hangs off the end of an On Top display. [TFS
62313]
- At runtime, the trend object will be brought to the foreground of the display, so any objects that are
drawn over a trend object will be covered or hidden.
- Zooming/Panning: Selecting inside the trend and dragging the cursor will zoom in the selected area
and set the X-axis to that selection. In the Silverlight trend, this action used to pan through the data.
Panning is now accomplished using the scroll bar under the trend.
- FactoryTalk ViewPoint trends no longer support the export of the displayed trend to CSV file.
- FactoryTalk ViewPoint trends display a value bar that follows the cursor is inside the trend. The value
bar cannot be fixed and moved across the trend.
Conversion to HTML 5
- FactoryTalk ViewPoint trends do not support the creation of trend snapshots.
- FactoryTalk ViewPoint trends do not include a value bar that can be moved across the trend.
- Microsoft Silverlight is not required to view a FactoryTalk ViewPoint web application.
- Text alignment is not maintained in the published FactoryTalk ViewPoint application. When a
FactoryTalk View application contains text objects, embedded variables, or objects containing text
(such as captions), the alignment specified in the FactoryTalk View application is not maintained
when the application is published to ViewPoint. All text in the FactoryTalk ViewPoint application is
shown left-aligned.
- The appearance of text by font size or weight may vary by browser and device platform.
- The appearance of truncated and word-wrapped text may vary by browser and device platform since
each of them handles scaled object width/height calculations differently. [TFS 49997]
Text
String and Numeric input
- String and Numeric inputs bring up the scratchpad for data entry, which must be clicked before data can
be entered.
-
When entering string or numeric data on a touch-device without an external keyboard attached, the
built-in device keyboard will automatically be presented to the user when possible.
-
When selecting a string or numeric data field, the display will automatically zoom in to the entry
field, making data entry easier. Following HTML5 standards, the display will not automatically
zoom out until the user clicks the display outside of the entry field. [351557, 355750]
- At runtime, string and numeric inputs cannot be hidden behind another object on the screen due
to the way input objects are handled by HTML and drawn on the screen. They will always
appear to the foreground of the display. [TFS 59187]
Alarms
- When an alarm object is drawn small or scaled to a small device, only the message and priority
columns are displayed. Selecting an alarm will show its complete details. The smallest size that the
alarm object will draw or scale down to is 250x250 pixels. [TFS 62410]
- The alarm object will always be drawn completely, even if it hangs off the end of an On Top display.
[TFS 60631]
- At runtime, the alarm object will be brought to the foreground of the display, so any objects that are
drawn over an alarm object will be covered or hidden.
Regional settings
- Regional settings for decimal displays, datetime format, and the like are supported only for the
default formats of a selected language. Custom formats made after the selected language will
not be shown. [TFS 59283, 59282]
- The behavior of regional settings varies by browser. Internet Explorer supports the regional
settings of Windows, while Google Chrome browser and Mozilla® Firefox® require the
language setting to be selected in the browser. [TFS 55075]
VeriSign Universal Root Certification Authority certificate
If the VeriSign Universal Root Certification Authority certificate does not exist on the local computer, the
certificate is installed while installing Rockwell Automation software. Use Microsoft Management Console
(MMC) to view the certificate in Console Root > Certificates (Local Computer) > Trusted Root
Certification Authorities > Certificates.
FactoryTalk Security
FactoryTalk users in a default FactoryTalk Security group (such as Administrators) are denied access to a
FactoryTalk ViewPoint client. The error message shown is "Unauthorized: You are not authorized to view
display displayname."
The FactoryTalk Security user group, Administrators, cannot currently be used for FactoryTalk ViewPoint
Security. If FactoryTalk user belongs to the Administrators group, the FactoryTalk User should be added
to a different role or FactoryTalk Security user group that the desired permissions can be given to.
Mitigation for Microsoft DCOM Hardening patch
In response to Microsoft Distributed Component Object Model (DCOM) Hardening patch (MS KB5004442),
the minimum DCOM authentication level used by Rockwell Automation products was raised to Packet
Integrity.
IMPORTANT: Installing this product’s latest version with earlier unpatched versions of other FactoryTalk products or products
using Classic OPC DA connections may cause a loss of connectivity due to the difference in DCOM authentication level used.
For additional information, see the Knowledgebase Document ID:
IN39461 - Microsoft DCOM Hardening Information TOC.
Navigation
-
FactoryTalk ViewPoint application pages intermittently fail to load in the browser. When using a
browser to navigate (forward, back, or history) within FactoryTalk ViewPoint applications, some
pages may not load. You will not receive an error message and the only indication will be the
browser page will remain the same, but the address bar will change to the new page.
To avoid this problem, refresh or reload the browser page.
-
When cookies are disabled, FactoryTalk ViewPoint does not present pages properly.
Depending on the browser, FactoryTalk ViewPoint will prevent user sign-ins, show blank
pages, or show an error that cookies are disabled.
To avoid this problem, enable cookies.
Publishing displays
Network Distributed application conversion
Publishing displays
- Background publishing does not work after upgrading to a new release of ViewPoint.
To avoid this problem, after upgrading FactoryTalk ViewPoint, manually republish the application. This
will allow the background publishing to operate properly and is only necessary the first time an
application is accessed after an upgrade.
KEPServer
If you are using KEPServer Enterprise as an OPC server with FactoryTalk View and FactoryTalk
ViewPoint version 9.00.00 or later, you will not be able to access the tag value. The cause is that the
security enhancements in FactoryTalk View and FactoryTalk ViewPoint version 9.00.00 or later affect
the communications. To access the tag value, the additional Distributed Component Object Model
(DCOM) configuration is required for KEPServer Enterprise on the computers.
For more information about the configuration, see Appendix, "Troubleshoot KEPServer Enterprise" in the
FactoryTalk View Installation Guide.
Application notes for FactoryTalk ViewPoint for Machine Edition.
Unsupported FactoryTalk View features
Graphic displays that contain unsupported objects or features can still be published to a FactoryTalk
ViewPoint server and viewed in a web browser. During the publishing process, unsupported objects are
removed from displays, so that they do not interfere with the web application.
Each unsupported object or feature generates a warning during publishing, which is recorded in the
publishing report. To check the report, after publishing is finished, click the link View publishing report.
FactoryTalk ViewPoint does not support the following FactoryTalk View objects or features:
Multiple language support
FactoryTalk ViewPoint only supports English language in display names, local message file names, image
file names, and parameter file names.
Graphic display properties
- Resize and position settings are ignored when a display is opened in a web browser. Displays
are scaled to fit the web browser window by default.
- Startup and shutdown commands are not supported.
- A to P codes for securing displays at run time are not supported.
Graphic objects and object properties
- When detected in a display, a FactoryTalk View trend object is replaced with a FactoryTalk ViewPoint
trend.
- FactoryTalk ViewPoint trend does not support the following properties specified in the Trend Properties
dialog box:
|
Tabs
|
Properties
|
|
General
|
- Chart style: XY Plot
- Chart update mode, except for Automatic
Refresh Rate, which is supported
|
|
Display
|
All
|
|
Pens
|
- Pen Attributes, except for Visible, Width, Min,
and Max, which are supported
|
|
X-Axis
|
- Chart time range, except for Time span, which is
supported
- Display options, except for Display Scale, which is
supported
|
|
Y-Axis
|
- Minimum / maximum value options: Custom -
Controlled by tag
- Display options, except for Display Scale, which is
supported
- Scale options
|
|
Overlays
|
All
|
|
Templates
|
All
|
|
Common
|
Other
|
|
Connections
|
|
- The Enter and Enter Handshake connections are not supported.
Object animation
- Horizontal and vertical sliders show current positions only. The sliders do not respond when dragged.
- Only supports the hyperlink animation when the hyperlink is an absolute path to a public web
resource, for example, http://
literature.rockwellautomation.com/idc/groups/literature/documents/qs/ftvp-qs002_-en-e.pdf.
Logic and control functions
- FactoryTalk ViewPoint does not support functions.
- CurrentUserName() returns "WebClientUser", and the other security functions return "FALSE".
Unattended or silent install
Use command-line parameters to perform an unattended or silent installation of the software.
Command-line parameters
The following table identifies the installation command-line parameters. Command-line parameters are
case-insensitive. However, if a specified value includes a space, be sure to enclose the value in quotation
marks (for example, "value with spaces").
|
Parameter
|
Description
|
|
/?
|
Shows the usage options for installation parameters.
|
|
/Q
|
Silent Install, install runs in a quiet mode without any user interface.
This parameter is recommended when deploying the software installation using an IT tool or script, and don’t
expect any error or restart messages. When using this parameter, check the error codes, and respond as
needed. For example, if the installation returns error code 1641, then the IT tool or script should restart the
computer and relaunch the installation after restart.
This parameter is required if /QS is not specified.
|
|
/QS
|
Unattended Install, install runs in a quiet simple mode and shows progress through the UI, it does not accept
any input but still shows error or restart messages.
When using this parameter, the installation will stop and display a prompt if there are error or restart
messages. For example, if an immediate restart is required to complete the install, a restart message will be
displayed to confirm the restart. Installation resumes automatically from the point of interruption after restart.
This parameter is required if /Q is not specified.
|
|
/IAcceptAllLicenseTerms
|
Acknowledges acceptance of the license terms.
This parameter is required for /Q or /QS parameters.
|
|
/AutoRestart
|
Automatically restarts the computer after the installation is complete. Used when a restart is required to
complete the installation. This parameter is optional. If this parameter is not used silent install (/Q) will return either error code 1641 or 3010 if a restart is required, and unattended install (/QS) will result in a confirmation prompt that must be agreed to before the installation is completed.
|
|
/Record
|
Records the installation options chosen to a recording file. When applied, the installation process automatically
creates a recording file
<Product>.REC that is stored in this path:
%USERPROFILE%\Desktop. This parameter is
optional.
|
|
/Playback="value"
|
Plays back a recording file to specify the installation options. The value is the full path of
the REC file to be used. For example,
/Playback="C:\Users\<Username>\Documents\<Product>.REC". This parameter is optional.
|
|
/Repair
|
Runs a repair operation on the installed
products. This parameter is optional.
|
|
/Uninstall
|
Uninstalls the product.
|
|
/SetupLanguage="value"
|
Specifies which language will be shown during the
install process. The value must be one of the
following:
- ENU
- CHS
- DEU
- ESP
- FRA
- ITA
- JPN
- KOR
- PTB
For example, /SetupLanguage="ENU".
This parameter is optional. If this parameter is not used, the default language is the current user or operating
system user interface language.
|
|
/InstallDrive="value"
|
Specifies the
installation drive.
For example,
/InstallDrive="D:".
This parameter is optional. If this parameter is not used, the default install drive is C:.
|
|
/IgnoreWarning
|
Specifies that the setup ignores warnings and continues.
This parameter is optional. If it is not specified, the setup exits when a warning occurs.
|
|
/SerialNumber="value"
|
Specifies the serial number of the software being installed. This is used to activate the software during
installation.
This parameter is optional. If it is not specified, the software must be activated manually after installation
if activation is required. Some software does not require activation. If activation is not required, this
parameter is not available.
|
|
/ProductKey="value"
|
Specifies the product key used to get activation keys during installation.
This parameter is optional. If it is not specified, the software must be activated manually after installation if
activation is required. Some software does not require activation. If activation is not required, this parameter is not available.
|
|
/Version="value"
|
Specifies the version of the software to activate, which corresponds to the product version associated with the
SerialNumber and ProductKey. This parameter is optional. If it is not specified, the installer will use the most
recent product version available.
Some software does not require activation. If activation is not required, this parameter is not available.
|
|
/NoHTTPS
|
Specifies that the setup turns off HTTPS.
This parameter is optional. If it is not specified, the setup turns on HTTPS for communication, and a TLS
certificate must be configured after installation.
|
Error codes
The following table identifies the error codes that can be returned by an installation.
|
Error Code
|
Value
|
Description
|
|
ERROR_SUCCESS
|
0
|
The installation completed successfully.
|
|
ERROR_INVALID_PARAMETER
|
87
|
One of the parameters was invalid.
|
|
ERROR_INSTALL_USEREXIT
|
1602
|
The installation was canceled by the user.
|
|
ERROR_INSTALL_FAILURE
|
1603
|
A fatal error occurred during installation.
|
|
ERROR_BAD_CONFIGURATION
|
1610
|
The configuration data for this product is
corrupt. Contact your support personnel.
|
|
ERROR_SUCCESS_REBOOT_INITIATED
|
1641
|
The installer has initiated a restart. After
restart, the installation will continue.
|
|
ERROR_SUCCESS_REBOOT_REQUIRED
|
3010
|
A restart is required to complete the
installation. After restart, the product is
successfully installed.
|
|
ERROR_REBOOT_PENDING
|
3012
|
Restart pending. Restart the computer for the
installation to continue.
|
|
ERROR_SUCCESS_NOT_APPLICABLE
|
3013
|
The installation cannot proceed because the
products are already installed.
|
|
ERROR_SUCCESS_WARNING_REBOOT
|
3014
|
The installation succeeded with warnings.
Check the installation log file for details. To
complete the installation, restart the computer.
|
Installation or upgrading
Installation
Installing FactoryTalk ViewPoint Server on a computer with FactoryTalk View Studio for Machine Edition
installed alters Studio behavior. After installing the FactoryTalk ViewPoint Server on an Engineering
workstation that has only FactoryTalk View Studio for Machine Edition installed, Studio behaves as if a full
install of FactoryTalk Supervisory Edition was done.
Upgrading FactoryTalk ViewPoint from version 8.00.00 or earlier
Upgrading to FactoryTalk ViewPoint version 10.00.00 from version 8.00.00 or earlier changes existing
FactoryTalk ViewPoint application and object behavior. Review the following list to determine if design or
configuration changes are required in your application before performing an upgrade.
Republish all displays and download a new .mer file to each terminal after upgrading to FactoryTalk
ViewPoint version 10.00.00.
Trend
-
When the trend object is drawn small or scaled to a small device, the pen legend and X-axis scroll
bar is hidden to help maximize the displayed trend area. Choose trend settings to re-enable. The
smallest size that the alarm object will draw or scale down to is 300x400 pixels. [TFS 62868,
64564, 63838]
- The Y-axis of the trend object is automatically rendered based on the size of the browser window.
Custom Y-axis settings may not be displayed if the size of the browser window is very different from
the original display size. [TFS 69476]
- The trend object will always be drawn completely, even if it hangs off the end of an On Top display. [TFS
62313]
- At runtime, the trend object will be brought to the foreground of the display, so any objects that are
drawn over a trend object will be covered or hidden.
- Zooming/Panning: Selecting inside the trend and dragging the cursor will zoom in the selected area
and set the X-axis to that selection. In the Silverlight trend, this action used to pan through the data.
Panning is now accomplished using the scroll bar under the trend.
- FactoryTalk ViewPoint trends no longer support the export of the displayed trend to CSV file.
- FactoryTalk ViewPoint trends display a value bar that follows the cursor is inside the trend. The value
bar cannot be fixed and moved across the trend.
Conversion to HTML 5
- FactoryTalk ViewPoint trends do not support the creation of trend snapshots.
- FactoryTalk ViewPoint trends do not include a value bar that can be moved across the trend.
- Microsoft Silverlight is not required to view a FactoryTalk ViewPoint web application.
Text
- The appearance of text by font size or weight may vary by browser and device platform.
- The appearance of truncated and word-wrapped text may vary by browser and device platform since
each of them handles scaled object width/height calculations differently. [TFS 49997]
String and Numeric input
- String and Numeric inputs bring up the scratchpad for data entry, which must be clicked before data can
be entered.
- When entering string or numeric data on a touch-device without an external keyboard attached, the
built-in device keyboard will automatically be presented to the user when possible.
-
When selecting a string or numeric data field, the display will automatically zoom in to the entry
field, making data entry easier. Following HTML5 standards, the display will not automatically
zoom out until the user clicks the display outside of the entry field. [351557, 355750]
- At runtime, string and numeric inputs cannot be hidden behind another object on the screen due
to the way input objects are handled by HTML and drawn on the screen. They will always
appear to the foreground of the display. [TFS 59187]
Regional settings
- Regional settings for decimal displays, datetime format, and the like are supported only for the
default formats of a selected language. Custom formats made after the selected language will
not be shown. [TFS 59283, 59282]
- The behavior of regional settings varies by browser. Internet Explorer supports the regional
settings of Windows, while Google Chrome browser and Mozilla® Firefox® require the
language setting to be selected in the browser. [TFS 55075]
Local message files created in RSView 4.00 (CPR 7) and earlier
VeriSign Universal Root Certification Authority
If the VeriSign Universal Root Certification Authority certificate does not exist on the local computer, the
certificate is installed while installing Rockwell Automation software. Use Microsoft Management Console
(MMC) to view the certificate in Console Root > Certificates (Local Computer) > Trusted Root
Certification Authorities > Certificates.
FactoryTalk Security
FactoryTalk users in a default FactoryTalk Security group (such as Administrators) are denied access to a
FactoryTalk ViewPoint client. The error message shown is "Unauthorized: You are not authorized to view
display displayname."
The FactoryTalk Security user group, Administrators, cannot currently be used for FactoryTalk ViewPoint
Security. If FactoryTalk user belongs to the Administrators group, the FactoryTalk User should be added
to a different role or FactoryTalk Security user group that the desired permissions can be given to.
Navigation
-
FactoryTalk ViewPoint application pages intermittently fail to load in the browser. When using a
browser to navigate (forward, back, or history) within FactoryTalk ViewPoint applications, some
pages may not load. You will not receive an error message and the only indication will be the
browser page will remain the same, but the address bar will change to the new page.
To avoid this problem, refresh or reload the browser page.
-
When cookies are disabled, FactoryTalk ViewPoint does not present pages properly.
Depending on the browser, FactoryTalk ViewPoint will prevent user sign-ins, show blank
pages, or show an error that cookies are disabled.
To avoid this problem, enable cookies.
Publishing displays
- Publishing displays
FactoryTalk ViewPoint client did not get updated after removing Global Object from FactoryTalk View
Studio. After the Global Object is removed, the publishing process does not pick up the change
therefore the Global Object still appears on the display. The same results are seen if the Global
Object is deleted (instead of being removed) in FactoryTalk View. This anomaly occurs in ViewPoint
publishing with any display that has missing references (Global Objects, parameter files, macros,
and alike), not just specifically Global Objects.
To avoid this problem, manually republish the application.
KEPServer
If you are using KEPServer Enterprise as an OPC server with FactoryTalk View and FactoryTalk
ViewPoint version 9.00.00 or later, you will not be able to access the tag value. The cause is that the
security enhancements in FactoryTalk View and FactoryTalk ViewPoint version 9.00.00 or later affect the
communications. To access the tag value, the additional Distributed Component Object Model (DCOM)
configuration is required for KEPServer Enterprise on the computers.
For more information about the configuration, see Appendix, "Troubleshoot KEPServer Enterprise" in the
FactoryTalk View Installation Guide.