Release Notes

( 9701-VWMx ) FactoryTalk® View Machine Edition is machine-level HMI software. [FTView, FTViewME, FTView ME, RSView, RSViewME, FactoryTalk View ME]
Version 16.00.00 (released 10/2025)

Catalog Number FactoryTalk View Machine Edition 

These release notes describe version information for FactoryTalk View Machine Edition, version 16.00.00 (released 10/2025).

Requirements

This release has the following requirements.

System requirements for FactoryTalk View ME version 16.00.00

FactoryTalk View ME works within the system requirements of all Rockwell Automation® software products. For the latest compatibility information, refer to the Product Compatibility and Download Center.
Hardware requirements
The hardware required to run FactoryTalk View ME depends on the demands that an application places on the system. Greater demand requires more powerful hardware.
Minimum
Recommended
Modern CPU specifications, including core and thread counts, base frequency, and max turbo frequency, significantly impact performance. For optimal results, we recommend using higher-end hardware configurations featuring a process speed of at least 2.4 gigahertz.
Faster processors and more memory yield better performance. Typically, Windows 11 requires more system resources than Windows 10. Additionally, ensure that the hard drive has sufficient disk space to provide virtual memory at least twice the size of the physical RAM.
Software requirements
The following operating systems are supported and recommended* in FactoryTalk View ME:
*The recommended operating systems have priority for Microsoft Patch Qualifications with Rockwell Automation software.
**Windows Server Datacenter editions are supported. The key difference between Windows Server Standard and Datacenter edition is how Microsoft licenses the operating system. Windows Server Standard includes licensing for up to two virtual machines per core license,
making it suitable for lightly virtualized environments. Datacenter edition allows unlimited virtual machines per core license, offering better value for highly virtualized or cloud-scale deployments.
***Windows 11 IoT Enterprise LTSC and Windows 11 Enterprise LTSC are binary equivalents but are licensed differently. Windows 10 IoT Enterprise LTSC and Windows 10 Enterprise LTSC are binary equivalents but are licensed differently.
Rockwell Automation's software installation policy is based on the lifecycle information of Microsoft operating systems. If an operating system's lifecycle state is approaching its end, you may encounter a warning message when trying to install Rockwell Automation software on it.
Microsoft lifecycle policy
Rockwell Automation installation warning policy
Rockwell Automation installation prevention policy
Fixed
Present a warning message during installation on Microsoft operating systems that are 18 months before Microsoft's extended end date.
Prevent installation on Microsoft operating systems that are six months past Microsoft's extended end date.
Modern
Present a warning message during installation on Microsoft operating systems that are 18 months before Microsoft's retirement date.
Prevent installation on Microsoft operating systems that are six months past Microsoft's retirement date.
The following table illustrates how the installation policy is applied using the current operating systems. For the latest compatibility information, refer to the Microsoft Lifecycle Policy and Product Compatibility and Download Center.
Operating system
Microsoft lifecycle policy
Extended end date
Retirement date
Installation warning
Installation prevented
Windows 11 Enterprise and Professional editions
Modern
None
None
None
None
Windows 10 Enterprise and Professional editions
Modern
None
October 14, 2025
April 14, 2024
April 14, 2026
Windows Server 2025 Standard and Datacenter editions
Fixed
October 10, 2034
None
April 10, 2033
April 10, 2035
Windows Server 2022 Standard and Datacenter editions
Fixed
October 14, 2031
None
April 14, 2030
April 14, 2032
Windows Server 2019 Standard and Datacenter editions
Fixed
January 9, 2029
None
July 9, 2027
July 9, 2029
Supported browsers
The following web browsers are supported for use with this release:
Supported SQL Server
FactoryTalk View ME version 16.00.00 supports SQL Server 2022 Express LocalDB as HMI tag databases.
Rockwell Automation test environment
Rockwell Automation tests software products under a standard configuration of operating systems and antivirus software. For additional information, see the Knowledgebase Document ID: PN24 - Rockwell Software Products and Antivirus Software.
Security requirements
To learn about designing a secure networking environment, review this publication:
To learn about implementing application-level security using FactoryTalk Security, review this publication:
To learn about designing and implementing an architecture with device-level security using CIP Security, review these publications:

Features

This release includes the following system features.

FactoryTalk View ME version 16.00.00 has the following new and enhanced features:
New features
Enhanced features

Corrected Anomalies in This Release

This release corrects the following anomalies.

Known Anomalies from Previous Releases

These anomalies are from previous releases but are still known in this release.

Functional Changes

This release has the following functional changes from the previous release.

FactoryTalk View ME version 16.00.00 has the following changes in functionality since the last release:

Application Notes

This release has the following application notes.

Unattended or silent install
Use command-line parameters to perform an unattended or silent installation of the software.
Command-line parameters
The following table identifies the installation command-line parameters. Command-line parameters are case-insensitive. However, if a specified value includes a space, be sure to enclose the value in quotation marks (for example, "value with spaces").
Parameter
Description
/?
Displays the usage options for installation parameters.
/Q
Silent Install, install runs in a quiet mode without any user interface.
This parameter is recommended when deploying the software installation using an IT tool or script, and don’t expect any error or restart messages. When using this parameter, check the error codes, and respond as needed. For example, if the installation returns error code 1641, then the IT tool or script should restart the computer and relaunch the installation after restart.
This parameter is required if /QS is not specified.
/QS
Unattended Install, install runs in a quiet simple mode and shows progress through the UI, it does not accept any input but still shows error or restart messages.
When using this parameter, the installation will stop and display a prompt if there are error or restart messages. For example, if an immediate restart is required to complete the install, a restart message will be displayed to confirm the restart. Installation resumes automatically from the point of interruption after restart.
This parameter is required if /Q is not specified.
/IAcceptAllLicenseTerms
Acknowledges acceptance of the license terms.
This parameter is required for /Q or /QS parameters.
/AutoRestart
Automatically restarts the computer after the installation is complete. Used when a restart is required to complete the installation.
This parameter is optional. If this parameter is not used, silent install (/Q) will return either error code 1641 or 3010 if a restart is required, and unattended install (/QS) will result in a confirmation prompt that must be agreed to before the installation is completed.
/Record
Records the installation options chosen to a recording file. When applied, the installation process automatically creates a recording file
<Product>.REC that is stored in this path: %USERPROFILE%\Desktop. This parameter is optional.
/Playback="value"
Plays back a recording file to specify the installation options. The value is the full path of the REC file to be used. For example,
/Playback="C:\Users\<Username>\Documents\<Product>.REC". This parameter is optional.
/HMIFolder="value"
Specifies the folder to store the HMI projects.
This parameter is optional. If you specify a folder that doesn’t exist yet, it will create a folder for you.
The larger the size of HMI projects, the longer it takes to set up the folder. Thus, if the size of HMI projects is large, we recommend that you use the HMI Projects Folder Path Config Utility to configure the new HMI projects folder after the installation.
/Repair
Runs a repair operation on the installed products. This parameter is optional.
/Uninstall
Uninstalls the product.
/RemoveApp
Deletes the application files when uninstalling the product. This parameter is optional.
/SetupLanguage="value"
Specifies which language will be displayed during the install process.
The value must be the one of the following:
  • ENU
  • CHS
  • DEU
  • ESP
  • FRA
  • ITA
  • JPN
  • KOR
  • PTB
For example, /SetupLanguage="ENU".
This parameter is optional. If this parameter is not used, the default language is the current user or operating system user interface language.
/Product="value"
Specifies which sub-products will be installed.
This parameter is required.
For FactoryTalk View ME, the value must be one of the following:
  • Studio for Machine Edition
  • Machine Edition Station for Windows
  • Stand-alone ME Transfer Utility
For FactoryTalk View SE, the value must be one of the following:
  • Studio Enterprise
  • Site Edition Server
  • Site Edition Client
  • Site Edition Station
  • FactoryTalk ViewPoint SE
  • Stand-alone FactoryTalk Linx Server
  • Stand-alone FactoryTalk Directory Server
/InstallDrive="value"
Specifies the installation drive.
For example, /InstallDrive="D:".
This parameter is optional. If this parameter is not used, the default install drive is C:.
/IgnoreWarning
Specifies that the setup ignores warnings and continues.
This parameter is optional. If it is not specified, the setup exits when a warning occurs.
/SerialNumber="value"
Specifies the serial number of the software being installed. This is used to activate the software during installation.
This parameter is optional. If it is not specified, the software must be activated manually after installation if activation is required. Some software does not require activation. If activation is not required, this parameter is not available.
/ProductKey="value"
Specifies the product key used to get activation keys during installation.
This parameter is optional. If it is not specified, the software must be activated manually after installation if activation is required. Some software does not require activation. If activation is not required, this parameter is not available.
/Version="value"
Specifies the version of the software to activate, which corresponds to the product version associated with the SerialNumber and ProductKey. This parameter is optional. If it is not specified, the installer will use the most recent product version available.
Some software does not require activation. If activation is not required, this parameter is not available.
/NoDemo
Skips the demo applications when installing the product. This parameter is optional.

Error codes

The following table identifies the error codes that can be returned by an installation.
Error Code
Value
Description
ERROR_SUCCESS
0
The installation completed successfully.
ERROR_INVALID_PARAMETER
87
One of the parameters was invalid.
ERROR_INSTALL_USEREXIT
1602
The installation was canceled by the user.
ERROR_INSTALL_FAILURE
1603
A fatal error occurred during installation.
ERROR_BAD_CONFIGURATION
1610
The configuration data for this product is corrupt. Contact your support personnel.
ERROR_SUCCESS_REBOOT_INITIATED
1641
The installer has initiated a restart. After restart, the installation will continue.
ERROR_SUCCESS_REBOOT_REQUIRED
3010
A restart is required to complete the installation. After restart, the product is successfully installed.
ERROR_REBOOT_PENDING
3012
Restart pending. Restart the computer for the installation to continue.
ERROR_SUCCESS_NOT_APPLICABLE
3013
The installation cannot proceed because the products are already installed.
ERROR_SUCCESS_WARNING_REBOOT
3014
The installation succeeded with warnings. Check the installation log file for details. To complete the installation, restart the computer.
Examples
The following examples show how to use the installation commands.
  • To install FactoryTalk View ME Station using the default settings during the installation process. (Silent install)

    Setup.exe /Q /IAcceptAllLicenseTerms /Product="Machine Edition Station for Windows"

  • To install the Chinese language version of the FactoryTalk View Studio for Machine Edition version 13.00.00 software on the D: drive and show the progress, error, or complete messages during installation, and restart the computer if necessary. The language shown during installation is Chinese. (Unattended install)
    Setup.exe /QS /IAcceptAllLicenseTerms /AutoRestart /SetupLanguage=CHS /Product="Studio for MachineEdition" /InstallDrive=D: /SerialNumber=12345ABCDE /ProductKey=ABCD2-34KDC / Version=13.00.00
  • To repair the installation of FactoryTalk View Studio for Machine Edition silently.
    Setup.exe /Q /Repair /Product="Studio for Machine Edition"
VeriSign Universal Root Certification Authority
If the VeriSign Universal Root Certification Authority certificate does not exist on the local computer, the certificate is installed while installing Rockwell Automation software. Use Microsoft Management Console (MMC) to view the certificate in Console Root > Certificates (Local Computer) > Trusted Root Certification Authorities > Certificates.
Communications
Windows operating system
KEPServer
RSNetWorx
If you use RSNetWorx, RSNetWorx version 10.00 or later is required. Rockwell Automation recommends RSNetWorx version 21.00 or later.
If you are under a current technical support contract, you may download RSNetWorx v21 or later from the Product Compatibility and Download Center.
To download RSNetWorx
  1. Click the Download Software Updates link and enter your Rockwell Automation Member identification.
  2. Enter your Company Name and the Software Serial Number for your current RSNetWorx.
  3. Follow the instructions to download and install the updated software product.
RSNetWorx v21.00 or later is also available in Studio Professional v21.00 or later. If you are not under a current technical support contract, you may purchase an update for RSNetWorx by contacting Rockwell Automation sales.
For information about RSNetWorx version 11.00 and earlier incompatibility with Rockwell Automation software products, see Knowledgebase Document ID: PN785 - Product Notice 2013-10-001 - RSNetWorx V11 and Prior Incompatibility with Rockwell Automation Software Products (201310001).
Network Security
For the latest network security considerations when using Rockwell Automation products, visit the Rockwell Automation Knowledgebase. For information about:
Internet security software
If third-party Internet firewall software is enabled on a computer, FactoryTalk View ME cannot be installed or run.
Before installing or running FactoryTalk View Studio, configure your internet firewall to allow the following .exe files to access the Internet:
  • C:\Program Files\Common Files\Rockwell\Rsvchost.exe
  • C:\Program Files\Common Files\Rockwell\RnaDirServer.exe
  • C:\Program Files\Common Files\Rockwell\VStudio.exe
  • C:\Program Files\Common Files\Rockwell\RNADirMultiplexor.exe
  • C:\Program Files\Common Files\Rockwell\RNADiagnosticsSrv.exe
  • C:\Program Files\Rockwell Software\RSLinx Enterprise\RSLinxNG.exe
Before installing or running FactoryTalk View ME Station, configure your Internet firewall to allow the following .exe files to access the Internet:
  • C:\Program Files\Rockwell Software\RSView Enterprise\MEMacroEditor.exe
  • C:\Program Files\Rockwell Software\RSView Enterprise\MERuntime.exe
  • C:\Program Files\Rockwell Software\RSView Enterprise\TagSrv.exe
After configuring your firewall software to allow these files internet access, restart your computer to apply the changes.
Tip: If your computer is running a 64-bit operating system, the files are in \Program Files (x86), instead of \Program Files.
User Account Control settings
User Account Control (UAC) is a feature of the Windows operating systems. This feature helps protect your computer from damage by programs that attempt to perform administrative tasks on your computer without your knowledge. By default, UAC is active and prompts you for administrative credentials, or to confirm that an executable file (.exe) associated with a menu item, button, or other item is safe to run.
Turning off UAC is not recommended.
This action
Prompts for authentication or confirmation before running this program
Setting or changing settings related to DeskLock
DeskLock2000.exe
In the Networks and Communications dialog box, double-clicking FactoryTalk Linx Communications
MERuntime.exe
In the FactoryTalk Linx Configuration dialog box, clicking Close
MERuntime.exe
In the Application Settings dialog box, double-clicking Device Shortcuts
MERuntime.exe
In the ShortCuts dialog box, clicking Close
MERuntime.exe
Clicking OK in the FactoryTalk View ME Station Startup dialog box
MERuntime.exe
Installing the FactoryTalk View software
Setup.exe
Uninstalling the FactoryTalk View software
Setup.exe and VSClean.exe
HMI server creating or opening impacted by SQL Server disk sector size limitation
Some newer storage devices and device drivers expose a disk sector size greater than the 4 KB limit supported by SQL Server. If a device exposes a larger sector size, SQL Server is unable to start due to the file system incompatibility.
This issue impacts the creating and opening of an HMI server that relies on SQL Server LocalDB. Specifically:
  • Opening an existing project may result in an error indicating that the required SQL Server LocalDB instance is not found.
  • Creating a new project may result in an error: Error creating HMI Server (0x80041118).
To verify the sector size of your system's drive C, run this command  fsutil fsinfo sectorinfo C: in the Command Prompt as an administrator, and then check the PhysicalBytesPerSectorAtomicity and PhysicalBytesPerSectorPerformance values.

If either value exceeds 4096, you can configure the system to emulate a 4 KB sector size using the

 ForcedPhysicalSectorSizeInBytes registry key.

  1. Run Registry Editor as an administrator.
  2. Navigate to Computer\HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\stornvme\Parameters\Device.
  3. Select Edit > New > Multi-String value and name it as ForcedPhysicalSectorSizeInBytes .
  4. Right-click the name, select Modify, and then type  * 4095 in the Value data box.
  5. Select OK.
  6. Restart the computer.
For more information, see Microsoft article: Troubleshoot errors related to system disk sector size greater than 4 KB.
Constraints when using FactoryTalk View version 6.10.00 or later
Different versions of FactoryTalk View ME use different databases.
FactoryTalk View ME version
Tag database
6.0 and earlier
Watcom
6.10, 7.0, 8.0, 8.10, 8.20, and 9.0
Microsoft SQL Server 2008 R2 Express
10.0, 11.0, and 12.0
Microsoft SQL Server 2014 Express LocalDB
13.0
Microsoft SQL Server 2019 Express LocalDB
14.0 and later
Microsoft SQL Server 2022 Express LocalDB
When installing FactoryTalk View ME version 6.10.00 or later:
  • On a 32-bit operating system, Watcom database and SQL Server database will be installed.
  • On a 64-bit operating system, only SQL Server database will be installed.
Due to this difference, some constraints with using FactoryTalk View ME version 6.10.00 or later are introduced on a 64-bit Windows OS.
To open or convert an application created with FactoryTalk View version 10.0 or later in FactoryTalk View version 9.0 or earlier, see Knowledgebase Document ID: QA48248 - FactoryTalk View ME: To open or convert the runtime application in version 9.0 or earlier.
For more information about constraints with creating and running MER on a 64-bit Windows operating system, review Appendix D, "Constraints when using FactoryTalk View version 6.10.00 or later" in FactoryTalk View ME Installation Guide for details.
Component names
The names for the following FactoryTalk View Studio components do not support extended ASCII characters or UNICODE characters:
  • Application
  • HMI server
  • Data server
  • HMI tag
  • FactoryTalk Linx shortcut
  • design time application file (.med)
  • All FactoryTalk View application components, including graphic displays, parameter files, macro files, and data log files
Application Manager
  • If a FactoryTalk View ME application is created on a computer whose operating system is in one language, such as the English version of Windows, and is later restored on another operating system that is in another language, such as the German version of Windows, unexpected errors may arise when the application name includes more than 16 characters.
    To avoid this problem:
    1. Open or restore the application on an operating system that is in the original language, the English version of Windows in this example.
    2. On the English version of Windows operating system, use Application Manager to rename the application to 16 characters or less and to back up the application to an APA file.
    3. Restore the APA file on the operating system that is in another language, the German version of Windows in this example.
  • If a FactoryTalk View ME application is closed, but FactoryTalk View Studio remains open, the Application Manager cannot delete or copy the closed application. The Application Manager does not recognize the application as being closed.
    To avoid this problem, open another application in FactoryTalk View Studio or close FactoryTalk View Studio before deleting or copying the application in Application Manager.
  • The existing Application Name dialog box cannot show the .mea application when restoring a legacy .mea application through FactoryTalk View ME directly.
    To avoid this problem, use Application Manager to convert the .mea application to an .med application. The .med application can then be imported using FactoryTalk View ME.
Data logging
  • If a FactoryTalk View ME application running on a Windows desktop platform is logging data to a custom path, attempting to access the log file (for example, to copy it) while data is being logged will stop the logging process and produce an error.
    To avoid this problem, access the log file after the data is logged.
  • If the custom path is set as C:\ in FactoryTalk View ME version 6.0 or later version applications (including the applications migrated from FactoryTalk View ME version 5.1 or earlier) running on Windows 7 or Windows Server 2008 operating system, the data logging process fails to start and cannot show the trend with historical data.
    To avoid this problem, rebuild the application and change the store path to other drives or a subfolder of drive C:, such as "C:\log" or "C\log\data".
  • If communication to a custom path fails while data is being written to the data log, data logging will stop.

    To resume data logging, shut down and restart the application.

  • When FactoryTalk View ME Station is configured to delete log files on startup, it will delete alarm log file, audit log file, data log model, and diagnostics.
Embedded variable
Embedded variables are not loaded until the text in the graphic object they are associated with is shown. If an object with an embedded variable has visibility animation, the embedded variable will not be activated until the object becomes visible. If the object later becomes invisible, the embedded variable will remain active.
For example, if a display containing an object with both visibility animation and embedded variables opens with the object invisible, and if the connection between the embedded variable and its tag is broken, FactoryTalk Diagnostics will not register communication errors for the object until the object becomes visible.
This also means that if one or more states of a multistate indicator include embedded variables, the variables will become active when those states are shown.
Firmware Upgrade Package
  • For the sake of expediency, we recommend upgrading via Ethernet or Compact Flash. The other protocols will work, however, the upgrade process may be extremely lengthy.
  • When upgrading the firmware directly on a PanelView Plus, PanelView Plus Compact, or PanelView Plus CE terminal, do not remove the Compact Flash card until you see the following message: "The firmware upgrade has been completed. Remove the Firmware Upgrade Card and then press the Exit button." Premature removal of the card will cause the upgrade to fail.
  • When the existing Machine Edition software on a PanelView Plus terminal is uninstalled during the upgrade, a multi-language message shows, stating that the software may be corrupted. The message includes two buttons, marked Download and Continue. Ignore this message, and do not press either of these buttons. Pressing either of these buttons will cause the Firmware Upgrade Wizard to become unstable.
  • Upgrading the firmware over a direct Ethernet or Serial connection will not work unless the PanelView File Transfer Utility is running on the terminal.
  • Files on the network are not available for upgrades. The upgrade files must be on the same computer as the Firmware Upgrade Wizard, otherwise the upgrade cannot be completed.
  • The firmware upgrade deletes any files and shortcuts in the startup directory (Storage card\Windows\Startup), including those not related to FactoryTalk View ME Station.
  • When you upgrade the firmware using a firmware upgrade (Compact Flash) card, the install procedure does not check the available space on the terminal's storage card. If the upgrade is larger than the existing firmware installation, be sure there is sufficient space available before starting the upgrade.
  • When downloading through a local connection, the progress dialog becomes locked and cannot be moved. If another application is opened over the dialog and then removed, the progress dialog does not refresh, but goes blank instead.
  • When the PanelView Plus, PanelView Plus Compact, and PanelView Plus CE terminals start, the characters EBC, followed by a letter or a number sequence, are shown on the top right corner of the screen: EBC-M or EBC 2.00.30, for example. If you see an EBC letter version earlier than "M", the Firmware Upgrade Wizard cannot perform the system upgrade.
  • Firmware upgrades to PanelView Plus and PanelView Plus Compact 400 and 600 terminals can be performed remotely provided the terminal has sufficient available space. Since the presence of KepServer drivers is the most likely to affect the amount of available memory, if the terminal includes KepServer drivers, or if the upgrade includes KepServer drivers, the download may fail. A Compact Flash card upgrade is recommended.
Global display
  • If an object contains undefined strings (for example, Chinese), and you choose to show undefined strings in the default language (for example, English), after you copy and paste the object, the duplicated object always shows the English language when you switch application languages. In this example, if the default language remains English and you did not choose to show undefined strings in the default language, when you change the application's current language to Chinese or French, the duplicated object still shows the English language, instead of a question mark (?).

    To avoid this problem, in the Language Configuration dialog box, clear the Display undefined strings using the default language check box before copying and pasting the object.

  • Graphic objects that show floating point values, such as numeric displays and input objects, show only five decimal places, and the fifth decimal place will be rounded if necessary.
  • Graphic displays, images, and graphic libraries that have the same name cannot be opened at the same time.
  • Objects that have rounded corners and use a wide line width (greater than 10) will not show the rounded corners on a PanelView Plus 7, PanelView Plus 6, PanelView Plus, PanelView Plus Compact, or PanelView Plus CE terminal.
  • If you are applying width or vertical position animation to text that uses Courier New font, the text will not animate properly.

    To avoid this problem, select a different font.

  • Scaled graphic objects add 1 to width or height settings when editing.

    To avoid this problem, choose one of the following methods:

    • Ungroup the objects before scaling, scale each object individually, and regroup if needed.
    • Set the height and width for the objects twice.
PanelView Plus and runtime
PanelView Plus 7 Standard application
  • In FactoryTalk View Studio version 8.20.00 and earlier, a PanelView Plus 7 Standard application cannot contain more than 25 displays or more than 200 alarms. In FactoryTalk View Studio version 9.00.00 and 10.00.00, a PanelView Plus 7 Standard application can contain up to 25 On Top displays, 25 Replace displays, and 500 alarms. In FactoryTalk View Studio version 11.00.00 and later, a PanelView Plus 7 Standard application can contain up to 100 displays and 500 alarms.
  • Using FactoryTalk View Studio version 9.00.00 or later, you can create a v8.20 or earlier version of PanelView Plus 7 Standard runtime application (.mer) that contains more than 25 displays or more than 200 alarms. The runtime application can be run on a PanelView Plus 7 Standard terminal installed with firmware version 8.20 or earlier, and can be restored to a design time application (.med) using FactoryTalk View Studio version 8.20.00 or earlier. However, from the restored application, you cannot create a PanelView Plus 7 Standard runtime application using FactoryTalk View Studio version 8.20.00 or earlier, because the number of alarms or displays exceeds the restriction defined in FactoryTalk View Studio version 8.20.00 or earlier.
  • Using FactoryTalk View Studio version 11.00.00 or later, you can create a v9.00 or v10.00 PanelView Plus 7 Standard runtime application (.mer) that contains more than 50 displays. The runtime application can be run on a PanelView Plus 7 Standard terminal installed with firmware version 9.00 or 10.00, and can be restored to a design time application (.med) using FactoryTalk View Studio version 9.00.00 or 10.00.00. However, from the restored application, you cannot create a PanelView Plus 7 Standard runtime application using FactoryTalk View Studio version 9.00.00 or 10.00.00, because the number of displays exceeds the restriction defined in FactoryTalk View Studio version 9.00.00 or 10.00.00. To maintain a PanelView Plus 7 Standard application that includes more than 50 displays, it is recommended to use FactoryTalk View ME v11.00.00 or later.
PanelView Plus terminal
  • Due to limited memory (RAM) on PanelView Plus family terminals, the extended tag property @Description cannot be passed through on PanelView Plus family terminals.
  • If the AM symbol, PM symbol, or Separator contains an ampersand (&), the string in the Time Format window is not shown correctly.
  • When a parameter list is used to open a graphic display on a PanelView Plus terminal, it does not show correctly if spaces are part of the string.
    To show strings correctly on a PanelView Plus terminal, define all strings without spaces.
ME Station
  • When there are multiple macros running in the application, or there are several displays popping up, if you shut down the application, you might experience a crash.
    To resolve this issue, reset the terminal.
  • On a PanelView Plus 7 or PanelView Plus 6 terminal, when saving files that have the same file name extension, and whose names start with the same eight characters on an SD card:
    • A maximum of 999 such files can be stored in a folder if the SD card is formatted using FAT32 (File Allocation Table 32).
    • More than 999 such files can be stored in a folder if the SD card is formated using exFAT (Extended File Allocation Table). For example, when exporting CSV files (YYYY_MM_DD_HH_mm_ss-<FileLabel>-TYPE.csv), you may need to format the SD card using exFAT to save more files.

      For more information about formatting an SD card using exFAT, see Appendix, "Format an SD card using exFAT" in the FactoryTalk View ME User's Guide.

  • On a PanelView Plus 7, PanelView Plus 6, PanelView Plus, PanelView Plus Compact, or PanelView Plus CE terminal, selecting the following option produces an error message in red: Terminal settings > Startup options > Startup tests > Select tests > CF External
    This message can safely be ignored. It does not indicate that the Compact Flash card has failed. This option is intended for use at the time of manufacture only.
  • If a Windows-linked user belongs to a Distribution type Windows-linked user group, the user cannot log in to the running application on desktops.
    To ensure that the user can log in, change the group type of the Windows-linked user group to Security.
  • When there are multiple macros running in the application, or there are several displays popping up, if you shut down the application, you might experience a crash.
    To resolve this issue, reset the terminal.
  • If you set up a primary domain controller with a backup domain controller to authenticate users for a PanelView Plus 7, PanelView Plus 6, PanelView Plus, or PanelView Plus CE terminal and the primary domain controller loses its network connection, the terminal will fail to authenticate through the backup domain controller.
    This will not happen if you authenticate domain users for personal computers.
Tag
  • If tag names, device shortcuts, or direct references include spaces, the Tag Substitution tool does not work for the tags in embedded variables.
    To avoid this problem, remove spaces in tag names, device shortcuts, and direct references when the tags are in an embedded variable.
  • If an HMI tag's Maximum property is increased, the change is not effective immediately.

    To apply the changes, close and reopen FactoryTalk View Studio.

  • Using a long integer tag with a value of 2,147,483,648 or greater will not allow an application to be validated or a converted MER file to be created from version 5.1 to 6.0. It is because that during the validation and conversion process, a tag is written in the command line (tag=2147483648), macro, or expression.
    To avoid this problem, keep the integer tag value less than 2,147,483,648.
  • When using tags, the values that are less than 53 bits are not shown correctly or may appear wireframed. It is because LINT, ULINT, or LWORD data types are not fully supported.

Impact of Microsoft deprecating VBScript

Microsoft announced the phased deprecation of VBScript in 2024. VBScript is now an optional feature beginning in Windows 11 24H2 and Windows Server 2025. Many FactoryTalk software products released before September 1, 2026, use VBScript during installation.

FactoryTalk View Machine Edition versions 16.00.00 and earlier require VBScript for installation. Installation will fail if VBScript is not enabled.

To mitigate the problem, enable VBScript manually. For more information, see the Knowledgebase Document ID: IN41397 - Impact of Microsoft deprecating VBScript. FactoryTalk software products released after September 1, 2026, no longer rely on VBScript.

Rockwell Automation recognizes that some of the terms that are currently used in our industry and in this publication are not in alignment with the movement toward inclusive language in technology. We are proactively collaborating with industry peers to find alternatives to such terms and making changes to our products and content. Please excuse the use of such terms in our content while we implement these changes.

Copyright © 2026 Rockwell Automation, Inc. All rights reserved.
Rockwell Automation, Allen-Bradley, and FactoryTalk are trademarks of Rockwell Automation, Inc.
To view a complete list of Rockwell Automation trademarks please click here.
Trademarks not belonging to Rockwell Automation are property of their respective companies.