Release Notes

ControlLogix Controllers
Version 30.051_kit1 (released 2/2017)

Catalog Number 1756-L72 Redundant (series B)

These release notes describe version information for 1756-L72 Redundant, version 30.051_kit1 (released 2/2017).

Security

This release includes security enhancements as a part of our ongoing efforts to improve security. For information regarding Rockwell Automation's vulnerability disclosure process, please reference the Rockwell Automation Vulnerability Policy.

Denial-of-Service Vulnerability That Affects Logix 5000™ Controllers (1042476,1042479)

Controllers
First Known in Firmware Revision
Corrected in Firmware Revision
CompactLogix™ 5370
20.011
33.016, 34.011 and later
Compact GuardLogix® 5370
28.011
33.016, 34.011 and later
ControlLogix® 5570
20.011
33.016, 34.011 and later
ControlLogix 5570 redundant
20.054
33.053, 34.051 and later
GuardLogix 5570
20.011
33.016, 34.011 and later
CompactLogix 5380
28.011
32.016, 33.011 and later
Compact GuardLogix 5380 SIL 2
31.011
32.016, 33.011 and later
Compact GuardLogix 5380 SIL 3
32.013
32.016, 33.011 and later
CompactLogix 5480
32.011
32.016, 33.011 and later
ControlLogix 5580
28.011
32.016, 33.011 and later
GuardLogix 5580
31.011
32.016, 33.011 and later


For a full list of the potentially affected Rockwell Automation products and a description of the vulnerability, see Knowledgebase Product Notice Logix Controllers Vulnerable to Denial-of-Service Attack.

CVE-2022-3157: Denial-of-Service Vulnerability That Affects Logix 5000™ Controllers (1256258, 1289747)

Controllers
First Known in Firmware Revision
Corrected in Firmware Revision
CompactLogix™ 5370
20.011
33.013, 34.011 and later
Compact GuardLogix® 5370
28.011
33.013, 34.011 and later
ControlLogix® 5570
20.011
33.013, 34.011 and later
GuardLogix 5570
20.011
33.013, 34.011 and later
ControlLogix 5570 redundant
20.054
33.052, 34.051 and later


For a full list of the potentially affected Rockwell Automation products and a description of the vulnerability, see Knowledgebase Product Notice Controllers Vulnerable to a Denial-of-Service Vulnerability.

  

CVE-2020-6998: Denial-of-Service Vulnerability That Affects Logix 5000™ Controllers (00228528)

Controllers
First Known in Firmware Revision
Corrected in Firmware Revision
CompactLogix™ 5370
20.011
33.011 and later
Compact GuardLogix® 5370
28.011
33.011 and later
ControlLogix® 5570
20.011
33.011 and later
GuardLogix 5570
20.011
33.011 and later
ControlLogix 5570 redundant
20.054
33.051 and later


For a full list of the potentially affected Rockwell Automation products and a description of the vulnerability, see Knowledgebase Product Notice CompactLogix 5370 and ControlLogix 5570 Controllers Vulnerable to Denial of Service Conditions due to Improper Input Validation.


  

Requirements

This release has the following requirements.

ControlLogix Redundancy System Components Revision 30.051_kit1

Catalog Numbers

This redundancy system revision includes the following:

Cat. No.
Module Description
Series
Firmware Revision
1756-EN2F
ControlLogix EtherNet/IP fiber communication module
C
10.0108
B or earlier
5.008 or 5.0284,5
1756-EN2T
ControlLogix EtherNet/IP communication module
D
10.0102,3
C or earlier
5.008 or 5.0284,5
1756-EN2TK
ControlLogix EtherNet/IP communication module (conformal coated)
D
10.0102,3
1756-EN2TXT
ControlLogix-XT™ EtherNet/IP communication module
D
10.0102,3
C or earlier
5.008 or 5.0284,5
1756-EN2TR
ControlLogix EtherNet/IP communication module
C
10.0103,6
B or earlier
5.008 or 5.0285,7
1756-EN2TRK
ControlLogix EtherNet/IP communication module (conformal coated)
C
10.0103,6
1756-EN2TRXT
ControlLogix-XT EtherNet/IP communication module
C
10.0103,6
B
5.0285,7
1756-CN2
ControlLogix ControlNet bridge
B
20.020
C
25.0051
1756-CN2R
ControlLogix redundant media ControlNet bridge
B
20.020
C
25.0051
1756-CN2RK
ControlLogix redundant ControlNet bridge (conformal coated) module
C
25.0051
1756-CN2RXT
ControlLogix-XT redundant media ControlNet bridge
B
20.020
C
25.0051
1756-L71
1756-L72
1756-L73
1756-L73XT
1756-L74
1756-L75
ControlLogix 5570 controllers, redundant
All
30.051
1756-RM2
ControlLogix redundancy module
All
20.009
1756-RM2K
ControlLogix redundancy module
All
20.009
1756-RM2XT
ControlLogix-XT redundancy module
All
20.009

(1) IMPORTANT: The 1756-CN2/C, 1756-CN2R/C, 1756-CN2RXT/C, 1756-CN2RK/C modules do not support firmware revisions previous to revision 25.004.

(2) IMPORTANT: The 1756-EN2T/D modules do not support firmware revisions previous to revision 10.006.

(3) Firmware revision 10.006 or later is digitally signed.

(4) IMPORTANT: The 1756-EN2T/C (or earlier) modules do not support firmware revision 10.006 or later.

(5) Firmware revision 5.028 is digitally signed firmware. Firmware revision 5.008 is unsigned firmware.

(6) IMPORTANT: The 1756-EN2TR/C modules do not support firmware revisions previous to revision 10.007.

(7) IMPORTANT: The 1756-EN2TR/B (or earlier) modules do not support firmware revision 10.007.

(8) IMPORTANT: The 1756-EN2F/C modules do not support firmware revisions before revision 10.009.

*ControlLogix 5570 controllers include all ControlLogix-XT™ and K versions.
**Includes the 1756-RM2K module.

Additional Resources for Revision 30.051_kit1

For more information on how to update your ControlLogix® redundancy system, see Replacement Guidelines: Update ControlLogix Redundancy Reference Manual, publication 1756-RM010.

For more information on how to install, configure and use your ControlLogix redundancy system, see the ControlLogix Redundancy User Manual, publication 1756-UM535.

ControlLogix Redundancy Compatible Software for Revision 30.051_kit1

Catalog Numbers

Software
Required Software Version, Min
CompareTool
6.10.00
ControlFLASH™
14.01.00
FactoryTalk® Services Platform
2.90.00 (CPR9-SR9)
FactoryTalk Activation Manager
4.00.02 (CPR9-SR9)
FactoryTalk Alarms and Events(1)
2.90.00 (CPR9-SR9)
FactoryTalk AssetCentre
6.10.00 (CPR9-SR7)
FactoryTalk Batch
12.01(3)
FactoryTalk View Site Edition(2)
9.00.00 (CPR9-SR9)
Redundancy Module Configuration Tool
8.04.01
RSLinx® Enterprise
5.90.00 (CPR9-SR9)
RSLinx Classic
3.90.00 (CPR9-SR9)
Studio 5000 Logix Designer®
30.00.00
RSNetWorx™ for ControlNet
26.00.00
RSNetWorx for EtherNet/IP
26.00.00

(1) You must download a FactoryTalk Alarm and Events patch in Rockwell Automation Knowledgebase Answer ID 1011396. The patch is available at http://www.rockwellautomation.com/knowledgebase/.

(2) The installation of FactoryTalk View Site Edition also installs FactoryTalk Services Platform, which installs FactoryTalk Alarms and Events. Also, if you download and install the latest FactoryTalk Services Patch Rollup, this patch automatically installs the patch for FactoryTalk Alarms and Events.

(3) Use the most recent FactoryTalk Batch Patch Roll-up with this redundancy firmware revision.

IMPORTANT: The following steps apply only to the FactoryTalk Alarms and Events installation.

  1. Install FactoryTalk View Site Edition.

This installation installs FactoryTalk Services Platform, which installs FactoryTalk Alarms and Events.

  1. Download and install the latest FactoryTalk Services Patch Rollup.

This installation automatically installs the patch for FactoryTalk Alarms and Events.

*ControlLogix 5570 controllers include all ControlLogix-XT™ and K versions.

Controller Restrictions in Redundancy Systems with Revision 30.051_kit1

Known Restrictions as of ControlLogix® Redundancy Revision 30.051_kit1       

This revision supports the following:

Catalog Numbers

1756-EN2T/D, 1756-EN2T/C, 1756-EN2TR:

1756-CN2, 1756-CN2R, 1756-CN2RXT, 1756-CN2RK:

1756-EN2T:

1756-EN2T, 1756-EN2TR, 1756-EN2TXT, 1756-EN2F:

ControlLogix 5570 redundant controllers*, 1756-EN2T, 1756-EN2TR, 1756-EN2TXT, 1756-EN2F:

CIP Sync Technology Included in Redundant Systems:

                  1.   The Grandmaster status transfers from the original primary controller to the new primary controller.
                        This transfer can take longer to complete than if Grandmaster status was transferred between devices
                         in a non-redundant system.

                  2.   The synchronization of the redundancy system can take longer when you use CIP Sync technology.

ControlLogix 5570 controllers*

1756-CN2, 1756-CN2R, 1756-CN2RXT, 1756-EN2T, 1756-EN2TR, 1756-EN2TXT, 1756-EN2F:

*ControlLogix 5570 controllers include all ControlLogix-XT™ and K versions.

1756-L7 Safety Certification

This version is certified to SIL 2. For more information, see Safety Certificate logix-ct007.

  
ControlLogix® 5570 Redundancy System Update Migration Paths

General Rules:
• Going to a later minor revision and/or kit is acceptable.
• Going to the next major revision is acceptable.
• Going through more than one major revision requires you to perform the RSU process multiple times.

Redundancy System Update Migration Path Limitations
  
From Firmware Revision
Firmware Revision Updates Conditionally Not Allowed*
20.058_kit3
24.052_kit1, 24.053_kit1
24.052_kit1
24.053_kit1
24.053_kit2
30.051_kit1, 30.051_kit2, 30.051_kit3
30.051_kit1
30.051_kit2
31.052_kit1, 31.052_kit2
30.051_kit3
31.052_kit1, 31.052_kit2, 31.052_kit3
30.051_kit4
31.052_kit1, 31.052_kit2, 31.052_kit3, 31.052_kit4
31.052_kit1
31.052_kit2
32.051_kit1
31.052_kit3
32.051_kit1
31.052_kit4
32.051_kit1, 32.051_kit2
31.052_kit5
32.051_kit1, 32.051_kit2, 32.051_kit3
32.051_kit1
32.051_kit2
33.051_kit1
32.051_kit3
33.051_kit1, 33.051_kit2, 33.052_kit1
32.051_kit4
33.051_kit1, 33.051_kit2, 33.052_kit1, 33.053_kit1
33.051_kit1
33.051_kit2
33.052_kit1
33.053_kit1
34.051_kit1
33.053_kit2
34.051_kit1, 34.052_kit
34.051_kit1
34.052_kit1
35.051_kit1
34.053_kit1
35.051_kit1, 35.052_kit1
35.051_kit1
35.052_kit1
35.053_kit1
36.051_kit1
36.051_kit1
36.052_kit1
37.051_kit1
37.051_kit1
37.051_kit2
38.051_kit1

*Depending on the modules used in the local rack, you may not be able to update the system with RSU. See Knowledgebase Technote ControlLogix®: Redundancy Firmware Bundle Revision History to see which modules are at an older firmware in the newer redundancy bundle.


Features

This release includes the following system features.

Component Change Detection
Product Feature in Firmware Revision 30
Catalog Numbers:
Component tracking allows you to quickly determine whether tracked routines, Add-On Instructions, and constant tags have been changed. The Studio 5000 Logix Designer® application creates a tracked value to indicate the current state of all components.
For more information, see theLogix5000 Controllers Information and Status Programming Manual, publication 1756-PM015.


Redundancy Module Configuration Tool for Revision 24.053 and 30.051

Catalog Numbers

IMPORTANT: You must uninstall any existing versions of the Redundancy Module Configuration Tool (RMCT) before you install version 8.4.1.0 of the RMCT. If you do not uninstall the previous versions, you can have difficulty if you try to uninstall version 8.4.1.0 later.

You can use 1756-RM2 or 1756-RM2XT redundancy modules to commission a redundant system. You can commission a system without any additional programming. However, there is additional functionality available if you use the modules with the RMCT.

This redundancy system revision requires the RMCT, version 8.4.1.0, that is packaged with this redundancy system revision bundle.

graphic

You can use the RMCT with the redundancy modules to complete these tasks:
For a complete list of RMCT functionality, see the ControlLogix Redundancy User Manual, publication 1756-UM535.

*ControlLogix 5570 controllers include all ControlLogix-XT® and K versions.
**Includes the 1756-RM2K module.
  

Corrected Anomalies in This Release

This release corrects the following anomalies.

ADC-enabled Project Causes a MNRF on the Secondary Controller (Lgx00187298 and Lgx00182783)

Corrected Anomaly in Firmware Revisions 24.053 and 30.051

Catalog Numbers: ControlLogix® 5570 Redundant Controllers

Known Anomaly first identified as of firmware revision 20.054

The secondary controller can experience a major non-recoverable fault (MNRF) when PowerFlex drives that support Automatic Drive Configuration (ADC) are in the application and one of these conditions occurs.

See Knowledgebase Article Secondary Controller Major Non Recoverable Fault Type 1 Code 60, Type 1 code 62 at version 20.054, 20.055, 20.056 and 24.052


  

New Primary Controller Experiences a T04:C82 SFC Jump Back Failure (Lgx00187293 and Lgx00187316)

Corrected Anomaly with Firmware Revisions 24.053 and 30.051

Known Anomaly First Identified as of Firmware Revision 24.052

Catalog Numbers: ControlLogix® 5570 Redundant Controllers

After a switchover, the new primary chassis controller experiences a Major Fault Type 4 Code 82 (T04:C82) SFC Jump Back Fault. This can occur in a redundant system when SFC’s are in a continuous task in the user’s application.

For information, see Knowledgebase Article ControlLogix Redundancy New Primary Experiences a T04:C82 SFC Jump Back Major Recoverable Fault


Specific Output Modules May Fail to Update after Switchover (Lgx00192444 and Lgx00193628)
Corrected Anomaly in Firmware Revisions 20.058, 24.053, and 30.051
Known Anomaly First Identified as of Firmware Revision 20.057
Catalog Numbers: ControlLogix® 5570 Redundant Controllers
When used in a redundant configuration and connected to specific module I/O devices, the processors can lose output control after a redundancy switchover. The controlling processor will not show a fault or error code indicating this anomalous behavior. However, outputs on these connected I/O devices will not change state.
For more information, see Knowledgebase Article Product Notice 2017-02-002 ControlLogix Firmware V20.057 and V24.052 Used in a Redundant Configuration with Specific Module Types - Outputs May Fail to Update After Switchover (201702002)


Assert on a Redundant Controller (LGX00121832)
  
Controllers
First Known in Firmware Revision
Corrected in Firmware Revision
ControlLogix® 5570 Redundant
19.052
20.054 and later
ControlLogix 5060 Redundant
19.052
20.054 and later

Under remote circumstances, an assert (also called a major non-recoverable fault, MNRF) can occur in the process of opening connections to I/O, during a system switchover. The assert can occur on either the secondary controller or the new primary controller. It is very rare for this assert to occur on the new primary controller.




Known Anomalies in This Release

This release has the following known anomalies.

Tracked State Value for Redundant Controller May Not Be Correct After A Switchover (Lgx00189950, Lgx00190153, Lgx00190152)

Corrected Anomaly in Firmware Revision 31.051

Known Anomaly first identified in version 30.00

Catalog Numbers: ControlLogix® 5570 Redundant Controllers

When you enable redundancy but do not retain test edits of a tracked routine, and switchover occurs with test edits running, the Tracked State value on the redundant controller will show the tracked state value of the controller with test edits, even though the test edits are not running in the redundant controller.

Follow one of these steps to work around the issue:

Important:
If you retain test edits and the test edits were the cause of the switchover, the test edits can cause the same fault on the redundant controller.


Redundancy-enabled Projects Sometimes Fail to Upload from The Controller Unless Original Download File Exists (Lgx00191976)

Corrected Anomaly as of Studio 5000 Logix Designer® v30.01.00 and v31.00.00

Known Anomaly first identified in version 30.00.00 of Studio 5000 Logix Designer

When you attempt to upload a redundancy-enabled project from the controller, the upload fails unless your computer contains the same project file that was originally downloaded.

The Studio 5000 Logix Designer application gives an error that the project has redundancy disabled and controller firmware with a minor revision of .49 is required.


Applications with PowerFlex drives in the I/O configuration can experience a major non-recoverable fault (MNRF) (00200734, 00200735, 00200600, 00200599)

Corrected Anomaly as of Firmware Revision 31.011 and 30.014 for these catalog numbers:

Corrected Anomaly as of Firmware Revision 31.011 and 30.013 for these catalog numbers:

Known Anomaly First Identified as of Firmware Revision 28.011 for these catalog numbers:

Known Anomaly First Identified as of Firmware Revision 20.011 for these catalog numbers:

If a controller already has an application loaded into it that contains PowerFlex drives in the I/O configuration, a MNRF (Major Non-Recoverable Fault) can occur when any of the following occurs:

For more information and workarounds, see Knowledgebase document 1067997.



Known Anomalies from Previous Releases

These anomalies are from previous releases but are still known in this release.

Some Faults Are Not Logged in The Controller Log (1061142, 1594647)

Controllers
First Known in Firmware Revision
Corrected in Firmware Revision
CompactLogix™ 5370
20.011
33.016, 34.011 and later
Compact GuardLogix® 5370
28.011
33.016, 34.011 and later
ControlLogix® 5570
20.011
33.016, 34.011 and later
ControlLogix 5570 redundant
20.054
33.053, 34.051 and later
GuardLogix 5570
20.011
33.016, 34.011 and later


The Controller Log feature does not properly log User Task Watchdog faults (Type 6 Code 1) in the Controller Log. For more information about the Controller Log feature, see the Logix 5000® Controllers Information and Status Programming Manual, publication 1756-PM015.


PCMD Returns Incorrect Error Code (1056295)

Controllers
First Known in Firmware Revision
Corrected in Firmware Revision
CompactLogix™ 5370
20.011
34.011
Compact GuardLogix® 5370
28.011
34.011
ControlLogix® 5570
20.011
34.011
ControlLogix 5570 redundant
20.054
34.051
GuardLogix 5570
28.011
34.011
CompactLogix 5380
28.011
34.011
Compact GuardLogix 5380 SIL 2
31.011
34.011
Compact GuardLogix 5380 SIL 3
32.013
34.011
CompactLogix 5380 Process
33.011
34.011
CompactLogix 5480
32.011
34.011
ControlLogix 5580
28.011
34.011
GuardLogix 5580
31.011
34.011
ControlLogix 5580 Process
33.011
34.011


Equipment Phase Command (PCMD) returns the incorrect error code “0x6003, HIGH_PRIORITY_OWNED” when it should return “0x6004, NOT_ATTACHED”


Controller Can Assert During The I/O Module Configuration Process (1024030, 00219969)

Controllers
First Known in Firmware Revision
Corrected in Firmware Revision
CompactLogix™ 5370
20.011
34.011
Compact GuardLogix® 5370
28.011
34.011
ControlLogix® 5570
20.011
34.011
ControlLogix 5570 redundant
20.054
34.051
GuardLogix 5570
28.011
34.011
CompactLogix 5380
28.011
33.011
Compact GuardLogix 5380 SIL 2
31.011
33.011
Compact GuardLogix 5380 SIL 3
32.013
33.011
CompactLogix 5480
32.011
33.011
ControlLogix 5580
28.011
33.011
GuardLogix 5580
31.011
33.011


Certain I/O modules send more configuration data than fits in a standard forward open (508 bytes) when the connection is being established.  Therefore, the configuration process can take longer to complete. Examples include E300™ Electronic Overload Relays, 1444 Dynamics, 1718 I/O, 1719 I/O, and many third-party I/O devices.

When the configuration data is being sent to the device, if you change the configuration through the Add-on Profile for the device and then apply the changes the controller can assert.


Grandmaster Clock Description Not Correctly Being Displayed (939979)

Controllers
First Known in Firmware Revision
Corrected in Firmware Revision
CompactLogix™ 5370
20.011
34.011
Compact GuardLogix® 5370
28.011
34.011
ControlLogix® 5570
20.011
34.011
ControlLogix 5570 redundant
20.054
34.051
GuardLogix 5570
20.011
34.011


Located in controller properties → Date Time → Advanced → Grandmaster Clock description could be shown as a blank description or could be showing old information. This does not impact time synchronization.



Functional Changes

This release has the following functional changes from the previous release.

ControlNet HMI Connections (Class 3) Not Maintained on Switchover
Functional Change First Identified as of Firmware Revision 30.051
Catalog Numbers: ControlLogix® 5570 Redundant Controllers
HMI connections (Class 3) are no longer maintained on switchover with communications over ControlNet®. Batch server now goes to a held state on switchover.
See ‘Bridge from an EtherNet/IP Network to a ControlNet Network’ in the ControlLogix 5570 Redundancy User Manual, publication 1756-UM535.


LINT Members must align on 8-byte Boundaries
Functional Change First Identified as of Firmware Revision 27
Beginning with version 27 of the Studio 5000 Logix Designer® application, LINT members must be aligned on 8-byte boundaries, and User-defined Data Types (UDT) that contain LINT members must be sized as a multiple of 8 bytes.
If you attempt to perform a Redundancy System Update (RSU) from V24.05x to V30.051 or later, and you have LINT tags inside a UDT, the Lock for Update attempt may fail.
This change impacts your Logix Designer application project if any of the following situations are true:
For more information, see these resources:

Application Notes

This release has the following application notes.

Firmware File Format

Application Note First Identified as of Firmware Revision 28.011

Catalog Numbers:

This firmware revision uses a new file format with an extension of .DMK. These files are named for easy identification, for example: 1756-L73_28.011.dmk.

ControlFLASH™ (version 13 or later) and ControlFLASH Plus™ software support the format. ControlFLASH software is automatically installed as part of the Studio 5000 Logix Designer® application installation. You can also download ControlFLASH and ControlFLASH Plus software from the Rockwell Automation Product Compatibility and Download Center (PCDC) separately, if necessary.

You are not required to install the new firmware file format. When you download .DMK files from the Rockwell Automation PCDC, ControlFLASH software automatically saves the folder location where the .DMK files were downloaded. As a result, ControlFLASH software can easily locate .DMK files.

You can use the Browse option to access and configure the folders that ControlFLASH software monitors, as shown.

graphic


Connection Drop Detected Between Producer and RCP on Switchover
Application Note for Firmware Revision 30.051

Catalog Numbers: ControlLogix® 5570 Redundant Controllers

For a controller in a remote chassis that has the primary redundancy controller in the I/O tree, or a redundancy controller that has a remote controller in the I/O tree, do not configure an Ethernet module in the remote I/O chassis for either Rack Optimized or Time Sync and Motion.


Rockwell Automation recognizes that some of the terms that are currently used in our industry and in this publication are not in alignment with the movement toward inclusive language in technology. We are proactively collaborating with industry peers to find alternatives to such terms and making changes to our products and content. Please excuse the use of such terms in our content while we implement these changes.

Copyright © 2026 Rockwell Automation, Inc. All rights reserved.
Rockwell Automation, Allen-Bradley, and FactoryTalk are trademarks of Rockwell Automation, Inc.
To view a complete list of Rockwell Automation trademarks please click here.
Trademarks not belonging to Rockwell Automation are property of their respective companies.